About 80,200 results
Open links in new tab
  1. Replacing a spanned "beam" with a cantilevered beam

    Dec 18, 2013 · (Beam Supported at Both Ends, Load at Center). I entered 4500lbs, 20inch beam, a modulus of elasticity of 1,400,000 (typical for wood joists?), and 37 for the moment of inertia. …

  2. engineering - How much load can a (wood) board support, if it is ...

    The nice thing about using simply supported beam for a simple plank is that the bending forces and deflections will be maximum values. If you use a fixed-fixed model there will be some …

  3. LVL Span Ratings and Beam Placement - Home Improvement …

    Jun 15, 2019 · The deflection changes more than you think it would with a multiple span I-joist vs a single span. I have found that homes with a triple ply LVL beam that span say more than 16' …

  4. Calculation Of Steel Beam - Home Improvement Stack Exchange

    Sep 7, 2021 · Midspan Deflection d' = 5 w L^4/384 E I w = total load/L E = Young's Modulus = 29000 ksi I = moment of inertia (in^4), see steel table for the selected beam. Ideally, the …

  5. Lateral bracing for steel beam - Home Improvement Stack Exchange

    Nov 4, 2020 · I’m installing a W16x26 steel beam, 20’ clear span underneath floor I-joists, 12” deep and 16”OC. The beam is plenty stout in terms of sheer and deflection but needs lateral …

  6. At a 6' span, how much can an SPF 2x4 turned on 3.5" end support?

    The ends are secured, so how much load can a 6' span of SPF 2x4 support when turned on 3.5"?

  7. What lower-profile options do I have to replace a triple 2x12 beam?

    The current beam is 2 2x8s with three 4x4 posts. I have had a engineer friend calculate the load for the roof (pic attached). His recommendation is to replace the beam with 3 2x12s to support …

  8. What size beam should be used for a 15' patio cover span?

    I'm looking into building a covered patio and am having a bit of difficulty finding the proper beam size required for the spans between posts. The cover will consist of either a ledger board attac...

  9. Flitch plate vs LVL for sistering an engineered beam

    Aug 15, 2019 · here's the quick skinny: I'm looking to reduce the deflection on a 13' beam before doing tile work on the above floor. It's a 5" wide parallam and it's deflecting at least 1/4". it's …

  10. deck - What is the maximum span for a beam made of two 2x10s …

    Jul 18, 2020 · This is for a deck. If I make a beam out of two 2x10s, what would the maximum span be? The beams will be 8 feet apart (joist span). They will be resting on posts. The …